Skip to main content

Update 20250106 January 17, 2025

Several improvements are included in this version, which also marks the end of support for ext2 and vfat file systems in favor of exfat, which is more stable, more robust and more widely supported by modern OSes.

In detail :

  • full support for systems in 19" cabinets
  • vfat and ext2 replaced by exfat, transferring data to the medium as soon as each block has been written (more robust transfers)
  • seedlink: disconnection/reconnection cycles sometimes resulted in old data being returned to the server
  • datalink: some adjustments to digitizerDatalinkStatus and addition of "datalink=realtime" and "datalink=disconnect" commands
  • auxiliary sensors: support for GMX500 weather station
  • network: second-level master mode (3 scanners cascaded on a single communication device)
  • web interface: display of network device details, clearer display of channel info on real-time visualization, display of external storage details...
  • external storage: release disk requests no longer invalidate permanent assembly requests
  • sensors: implementation of a special "MB3-ALL" sensor (1 MB3 per channel, with incremental location code for each channel)
  • HMI: equalization of LED intensity for D9-19 and optimization of LED refresh rate
  • GSM: in SMART mode, the system guarantees that the PPP connection will remain active for at least half the timeout period.

The firmware can be installed automatically from the scanner interface or downloaded by following this link.